Duct Leakage Testing in Waller, TX
Are you planning to get a Duct Leakage Test in Waller, TX? We help homeowners, builders, and contractors meet Texas energy code standards by providing accurate and timely duct leakage testing.
According to the 2018 IECC, newly built residential homes require duct leakage testing whenever any HVAC component, including ductwork or the air handler, is positioned outside the conditioned space. If compliance testing is needed for your home or building, we are prepared to deliver affordable and efficient testing services in Waller, TX, and its nearby regions.
What Is a Duct Leakage Test?
A duct leakage test assesses how much conditioned air is lost from the HVAC duct system. When ducts leak, they can result in:
- Extra energy expenses due to escaping heated or cooled air.
- Unstable indoor temperatures, causing discomfort in different rooms.
- Lower HVAC efficiency, forcing the system to work harder than necessary.
- Airborne dust and debris reducing indoor air quality and comfort.
A duct blower system is used in duct leakage testing to pressurize the ductwork and measure how much air is escaping. When excessive duct leakage occurs, sealing the system can optimize energy use and ensure compliance with local code regulations.


Do You Need a Duct Leakage Test in Waller, TX?
You may need a duct leakage test if:
- You are building a new home that requires energy code compliance.
- Your HVAC system’s ductwork or air handler is located outside the conditioned space (e.g., in an attic, crawl space, or garage).
- You are experiencing high energy costs and suspect leaky ducts
- Your home has uneven heating and cooling issues.
- You want to ensure your HVAC system is operating efficiently.
If your project or home requires duct leakage testing in Waller, TX, we ensure fast scheduling and same-day reporting to avoid setbacks.

Texas Energy Code Requirements for Duct Leakage
Under the 2018 IECC, homes in Texas must meet specific duct leakage limits:
- If the air handler or ducts are outside the thermal envelope, total duct leakage must be 4 CFM per 100 sq. ft. or lower.
- If the entire duct system is inside the conditioned space, a duct leakage test is not required.
Failing to meet these requirements can delay your project. Our expert technicians ensure quick and accurate testing to help you pass your inspection.

Our Duct Leakage Test Process
Our certified duct leakage testing process includes:
Step 1: System Preparation
- All registers and vents are sealed.
- The duct blaster fan is connected to the air handler or a return vent.
Step 2: Pressurizing the System
- The fan pressurizes the duct system to detect leaks.
- A digital pressure gauge measures total air loss.
Step 3: Analyzing the Results
- We compare the leakage rate to Texas energy code limits.
- If the system passes, we provide a certified report for compliance.
- If the system fails, we offer recommendations for sealing improvements.
We ensure your project stays on schedule by providing same-day results and guidance on how to meet duct leakage requirements.
Why Choose Us for Your Duct Leakage Test in Waller, TX?
When you choose us for your Duct Leakage Test in Waller, TX, you benefit from:
- Certified Professionals – We provide accurate, reliable, and code-compliant testing.
- Fast Scheduling – Get your test done quickly to avoid project delays.
- Same-Day Reports – Receive your results immediately.
- Affordable Pricing – Competitive rates with no hidden fees.
- Expert Guidance – If your home doesn’t pass, we help you find solutions.

Book Your Duct Leakage Test in Waller, TX Today
Need a duct leakage test in Waller, TX? We make the process fast and hassle-free. Call us today at (888) 496-4661 to schedule your test or book online!
Duct Leakage Testing Providers in Waller, TX
Below is a list of energy rater who provide duct leakage testing in Waller, Texas:
To be added to this list please email [email protected]