Duct Leakage Testing in Tolar, TX
Want a certified Duct Leakage Test in Tolar, TX? Our certified experts offer quick and precise duct leakage testing, ensuring homeowners, builders, and contractors comply with Texas energy code requirements.
Under the 2018 International Energy Conservation Code (IECC), new residential dwellings must undergo duct leakage testing if their HVAC system, including the ductwork or air handler, extends beyond the conditioned space. If you need compliance testing for your home or building, we provide prompt and affordable testing solutions in Tolar, TX, and the nearby communities.
What Is a Duct Leakage Test?
A duct leakage test calculates the volume of air that seeps out of the HVAC duct system. Duct leaks can lead to:
- Increased HVAC operating costs due to lost conditioned air.
- Temperature imbalances that result in an uncomfortable indoor environment.
- Poor HVAC efficiency, forcing the system to run longer and harder.
- Harmful particles circulating indoors because of compromised duct sealing.
A duct blower system is utilized in duct leakage testing to pressurize ductwork and calculate air leakage rates. If your ductwork is leaking too much air, sealing it can increase energy savings and help your home stay within code limits.


Do You Need a Duct Leakage Test in Tolar, TX?
You may need a duct leakage test if:
- You are building a new home that requires energy code compliance.
- Your HVAC system’s ductwork or air handler is located outside the conditioned space (e.g., in an attic, crawl space, or garage).
- You are experiencing high energy costs and suspect leaky ducts
- Your home has uneven heating and cooling issues.
- You want to ensure your HVAC system is operating efficiently.
If your home or construction project in Tolar, TX requires duct leakage testing, we guarantee quick scheduling and same-day results to keep your plans moving forward.

Texas Energy Code Requirements for Duct Leakage
Under the 2018 IECC, homes in Texas must meet specific duct leakage limits:
- If the air handler or ducts are outside the thermal envelope, total duct leakage must be 4 CFM per 100 sq. ft. or lower.
- If the entire duct system is inside the conditioned space, a duct leakage test is not required.
Failing to meet these requirements can delay your project. Our expert technicians ensure quick and accurate testing to help you pass your inspection.

Our Duct Leakage Test Process
Our certified duct leakage testing process includes:
Step 1: System Preparation
- All registers and vents are sealed.
- The duct blaster fan is connected to the air handler or a return vent.
Step 2: Pressurizing the System
- The fan pressurizes the duct system to detect leaks.
- A digital pressure gauge measures total air loss.
Step 3: Analyzing the Results
- We compare the leakage rate to Texas energy code limits.
- If the system passes, we provide a certified report for compliance.
- If the system fails, we offer recommendations for sealing improvements.
We ensure your project stays on schedule by providing same-day results and guidance on how to meet duct leakage requirements.
Why Choose Us for Your Duct Leakage Test in Tolar, TX?
When you choose us for your Duct Leakage Test in Tolar, TX, you benefit from:
- Certified Professionals – We provide accurate, reliable, and code-compliant testing.
- Fast Scheduling – Get your test done quickly to avoid project delays.
- Same-Day Reports – Receive your results immediately.
- Affordable Pricing – Competitive rates with no hidden fees.
- Expert Guidance – If your home doesn’t pass, we help you find solutions.

Book Your Duct Leakage Test in Tolar, TX Now
Need a duct leakage test in Tolar, TX? We make the process fast and hassle-free. Call us today at (888) 496-4661 to schedule your test or book online!