Duct Leakage Testing in Streetman, TX
Searching for a trusted company for a Duct Leakage Test in Streetman, TX? Our professional team ensures Texas energy code compliance with quick and precise duct leakage testing for homeowners, builders, and contractors.
As per the 2018 IECC, duct leakage testing is mandatory for new residential homes when components of the HVAC system, like the air handler or ductwork, are situated outside the conditioned space. If your home or building requires compliance testing, our experienced team offers high-quality and cost-efficient testing services in Streetman, TX, and surrounding locations.
What Is a Duct Leakage Test?
A duct leakage test examines the air loss occurring in the HVAC duct system. When ducts leak, the consequences may include:
- Unnecessary energy consumption resulting in higher bills.
- Inconsistent climate control, making it harder to stay comfortable indoors.
- Poor HVAC efficiency, forcing the system to run longer and harder.
- Pollutants infiltrating ductwork, leading to stale and unhealthy indoor air.
The duct leakage test is performed by pressurizing the ductwork with a duct blower system to measure the extent of air loss. If air leakage is higher than acceptable levels, duct sealing can enhance efficiency and help your home meet building code requirements.


Do You Need a Duct Leakage Test in Streetman, TX?
You may need a duct leakage test if:
- You are building a new home that requires energy code compliance.
- Your HVAC system’s ductwork or air handler is located outside the conditioned space (e.g., in an attic, crawl space, or garage).
- You are experiencing high energy costs and suspect leaky ducts
- Your home has uneven heating and cooling issues.
- You want to ensure your HVAC system is operating efficiently.
If your home or construction project in Streetman, TX requires duct leakage testing, we guarantee quick scheduling and same-day results to keep your plans moving forward.

Texas Energy Code Requirements for Duct Leakage
Under the 2018 IECC, homes in Texas must meet specific duct leakage limits:
- If the air handler or ducts are outside the thermal envelope, total duct leakage must be 4 CFM per 100 sq. ft. or lower.
- If the entire duct system is inside the conditioned space, a duct leakage test is not required.
Failing to meet these requirements can delay your project. Our expert technicians ensure quick and accurate testing to help you pass your inspection.

Our Duct Leakage Test Process
Our certified duct leakage testing process includes:
Step 1: System Preparation
- All registers and vents are sealed.
- The duct blaster fan is connected to the air handler or a return vent.
Step 2: Pressurizing the System
- The fan pressurizes the duct system to detect leaks.
- A digital pressure gauge measures total air loss.
Step 3: Analyzing the Results
- We compare the leakage rate to Texas energy code limits.
- If the system passes, we provide a certified report for compliance.
- If the system fails, we offer recommendations for sealing improvements.
We ensure your project stays on schedule by providing same-day results and guidance on how to meet duct leakage requirements.
Why Choose Us for Your Duct Leakage Test in Streetman, TX?
When you choose us for your Duct Leakage Test in Streetman, TX, you benefit from:
- Certified Professionals – We provide accurate, reliable, and code-compliant testing.
- Fast Scheduling – Get your test done quickly to avoid project delays.
- Same-Day Reports – Receive your results immediately.
- Affordable Pricing – Competitive rates with no hidden fees.
- Expert Guidance – If your home doesn’t pass, we help you find solutions.

Book Your Duct Leakage Test in Streetman, TX Today
Need a duct leakage test in Streetman, TX? We make the process fast and hassle-free. Call us today at (888) 496-4661 to schedule your test or book online!
Duct Leakage Testing Providers in Streetman, TX
Below is a list of energy rater who provide duct leakage testing in Streetman, Texas:
To be added to this list please email [email protected]