Duct Leakage Testing in Kurten, TX

Want a certified Duct Leakage Test in Kurten, TX? Our skilled professionals perform duct leakage tests quickly and precisely, helping homeowners, contractors, and builders adhere to Texas energy codes.

As outlined in the 2018 International Energy Conservation Code (IECC), all newly built residential dwellings are required to have duct leakage testing conducted when any section of the HVAC system, including ductwork or the air handler, is situated outside the conditioned space. If your home or building requires compliance testing, our experienced team offers high-quality and cost-efficient testing services in Kurten, TX, and surrounding locations.

What Is a Duct Leakage Test?

A duct leakage test determines the degree of air escaping from the HVAC duct system. Leaks in the ducts may cause:

  • Greater energy costs due to inefficient air distribution.
  • Improper heating and cooling balance, leading to a less comfortable environment.
  • Poor HVAC efficiency, forcing the system to run longer and harder.
  • Polluted indoor air from dust, mold, and debris getting into leaky ducts.

In duct leakage testing, a duct blower system forces air into the ductwork to determine the rate of air leakage. If your ductwork is leaking too much air, sealing it can increase energy savings and help your home stay within code limits.

Do You Need a Duct Leakage Test in Kurten, TX?

You may need a duct leakage test if:

If your project or home in Kurten, TX requires a duct leakage test, we provide immediate scheduling and results on the same day to keep you on track.

Texas Energy Code Requirements for Duct Leakage

Under the 2018 IECC, homes in Texas must meet specific duct leakage limits:

  • If the air handler or ducts are outside the thermal envelope, total duct leakage must be 4 CFM per 100 sq. ft. or lower.
  • If the entire duct system is inside the conditioned space, a duct leakage test is not required.

Failing to meet these requirements can delay your project. Our expert technicians ensure quick and accurate testing to help you pass your inspection.

Our Duct Leakage Test Process

Our certified duct leakage testing process includes:

Step 1: System Preparation

  • All registers and vents are sealed.
  • The duct blaster fan is connected to the air handler or a return vent.

Step 2: Pressurizing the System

  • The fan pressurizes the duct system to detect leaks.
  • A digital pressure gauge measures total air loss.

Step 3: Analyzing the Results

  • We compare the leakage rate to Texas energy code limits.
  • If the system passes, we provide a certified report for compliance.
  • If the system fails, we offer recommendations for sealing improvements.

We ensure your project stays on schedule by providing same-day results and guidance on how to meet duct leakage requirements.

Why Choose Us for Your Duct Leakage Test in Kurten, TX?

When you choose us for your Duct Leakage Test in Kurten, TX, you benefit from:

Book Your Duct Leakage Test in Kurten, TX Now

Need a duct leakage test in Kurten, TX? We make the process fast and hassle-free. Call us today at (888) 496-4661 to schedule your test or book online!

Duct Leakage Testing Providers in Kurten, TX

Below is a list of energy rater who provide duct leakage testing in Kurten, Texas:

To be added to this list please email [email protected]

Scroll to Top